Frame Level

The frame level is mainly used to check the straightness of various machine tools and other equipment, the correctness of the horizontal and vertical positions of installation, and can also check small inclination angles

Details

Tags

Product Description

 

Product name: Frame level, fitter level

 

There are two types of level: frame level and bar level. They are mainly used to check the straightness of various machine tools and other equipment, the correctness of the horizontal and vertical positions of installation, and can also check small inclination angles.

 

Instructions for using a frame level:

When measuring, wait until the bubbles are completely stationary before taking a reading. The indicated value on the level is the inclination value based on one meter, which can be calculated using the following equation:

Actual tilt value=scale indication x L x number of deviation grids

For example, the scale reading is 0.02mm/L=200mm, with a deviation of 2 grids.

So: actual tilt value=0.02/1000 × 200 × 2=0.008mm

 

Zero adjustment method:

Place the level on a stable flat plate and wait for the bubbles to stabilize before reading a, then rotate the instrument 180 degrees and place it in its original position to read b. The zero position error of the instrument is 1/2 (a-b); Then, loosen the fixing screws on the side of the spirit level, insert an 8mm hex wrench into the eccentric adjuster, rotate it, and perform zero adjustment. At this point, if it is found that the instrument is tilted 5 degrees forward and backward, and the movement of the level bubble is greater than 1/2 of the scale value, it is necessary to rotate the left and right adjusters again until the bubble does not move with the inclined surface of the instrument. Afterwards, it is necessary to check whether the zero position has moved. If the zero position does not move, tighten the fixing screw and adjust it.

 

Precautions for frame level:

  1. 1.Before use, clean the working surface of the instrument with gasoline and wipe it clean with degreased cotton yarn.
  2. 2.Temperature changes can cause measurement errors and should be isolated from heat and air sources during use.
  3. 3.Readings can only be made after the bubbles have completely stopped (approximately 15 seconds after the level is placed on the measuring surface)
  4. 4.To avoid errors caused by inaccurate horizontal zero position and parallelism of the working surface, check and adjust before use.

 

Product Parameter

 

Frame level specifications

 

product name

specifications

notes

frame levels

150*0.02mm

scraping

frame levels

200*0.02mm

scraping

frame levels

200*0.02mm

scraping

frame levels

250*0.02mm

scraping

frame levels

300*0.02mm

   scraping    

 

 

Product Detail Drawing

 

  • Read More About frame spirit level
  • Read More About frame levels
  • Read More About frame level
  • Read More About precision frame spirit level

 

RELATED NEWS

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Asset 3

Need Help?
Drop us a message using the form below.

en_USEnglish