• Example Image

Optical Composite Image Level

Optical Composite Image level Chishandiso Chishandiso: Iyo yemeso composite mufananidzo nhanho inoshandiswa zvakanyanya mukuyera ma gradients enzvimbo yakati sandara uye cylindrical pamusoro kune yakachinjika nzira; Kurongeka kwendege uye kutwasanuka kweslideway kana hwaro hwemuchina chishandiso kana optical mechanika chiridzwa pamwe nekurongeka kwekuisa chinzvimbo chemidziyo.

Details

Tags

Product Description

 
  1. 1.Kushandisa

Iyo optical composite image level inoshandiswa zvakanyanya mukuyera ma gradients enzvimbo yakati sandara uye cylindrical pamusoro kusvika kune yakachinjika nzira; Kurongeka kwendege uye kutwasanuka kweslideway kana hwaro hwemuchina chishandiso kana optical mechanika chiridzwa pamwe nekurongeka kwekuisa chinzvimbo chemidziyo.

 

  1. 2.Technical data

(1) yega yega kukosha kwekupedza kudzidza: ...0.01mm/m

(2) hukuru hwekuyera huwandu: ...0~10mm/m

(3) mvumo: ...1mm/mukati memita imwe... 0.01mm/m

Mukati mechiyero chakazara ... 0.02mm/m

(4) kutsauka kwendege panzvimbo yekushanda ... 0.0003mm/m

(5) imwe neimwe yekupedza kudzidza kukosha kweyero yemweya ... 0.1mm/m

(6) kushanda pamusoro (LW): ...165 48mm

(7) uremu hwemambure echiridzwa: ...2kgs.

  1.  
  2. 3.Kuumbwa kwechiridzwa:

Iyo composite image level inonyanya kuve nezvikamu zvinotevera senge micro inogadzirisa screw, nati, graduated disc, mweya level, prism, magnifying glass, lever pamwe ne base ine plain and v working surface.

 

  1. 4.Kushanda musimboti:

Iyo inoumbwa mufananidzo nhanho inoshandisa prism kuwana iyo mhepo bubble mifananidzo mune yemweya nhanho inoumbwa uye inokwidziridzwa kuti iwedzere kuverenga kuverenga uye inoshandisa lever uye micro screw transmitting system kusimudzira kuverenga kunzwisisika. Naizvozvo kana chidimbu chebasa chine 0.01mm/mm, chinogona kuverengwa nenzira kwayo muchikamu chemufananidzo (yero yemweya muchikamu chemufananidzo unonyanyoita basa rekuratidza zero).

 

  1. 5.Operating nzira:

Isa iyo inoumbwa chiyero chemufananidzo panzvimbo yekushanda yekuyera basa rekuyera uye gradient yekuyera workpiece inokonzera kusawirirana kweiyo tow air bubble mifananidzo; Tenderedza dhisiki rapedza kudzidza kusvika mapikicha e-tow air bubble apindirana uye kuverenga kunogona kuwanikwa nekukurumidza. Iyo chaiyo gradient yekuyera workpiece inogona kuverengerwa neinotevera formula:

Chaicho gradient=kukosha kwe gradient Fulcrum kureba Disc kuverenga

Fox muenzaniso: Disc kuverenga: 5 gradients; Sezvo iyi nhanho yemufananidzo inoumbwa yakashongedzwa nehukoshi hwayo hwegradient uye chinhambwe che fulcrum, ndiko kukosha kwe gradient: 0.01mm/m uye fulcrum chinhambwe: 165mm.

Saka: Chaiyo gradient=165mm 5 0.01/1000=0.00825mm

  1.  
  2. 6.Chiziviso chekushanda:

(1) usati washandisa, bvisa guruva remafuta nepeturu uye wobva wachenesa negauze rinonwisa.

(2) Shanduko yetembiricha ine simba guru pachiridzwa uye saka inofanirwa kupatsanurwa neinopisa sosi kudzivirira kukanganisa.

(3) Panguva yekuyera, tenderedza dhisiki rapedza kudzidza kusvika mifananidzo yemhepo yemhepo yanyatsopindirana uye ipapo kuverenga kwese kwakaringana uye kwakaipa kunogona kutorwa.

(4) If the instrument is found with in correct zero position, it may be adjusted; Put the instrument on a stable table and rotate the graduated disc to set the tow air bubble images coincide to get first reading a; Then turn the instrument by 180o and put back to its original place. Ra-rotate the graduated disc to get the tow air bubbles coincide to get the second reading b. So 1/2 (α +β ) is the zero deviation of the instrument. Loosen the three supporting screws on the graduated disc and press lightly by hand the embossed adjusting cap; Rotate the disc by 1/2 (α +β) to get the zero deviation and the point line composite; At last fasten the screws.

(5) Mushure mekushanda, nzvimbo yekushanda yechiridzwa inofanira kucheneswa uye yakaputirwa neasidhi isina, anhydrous, antirust mafuta uye antirust paper; Iise mubhokisi remapuranga wobva waichengeta munzvimbo yakachena yakaoma.

 

Hot Tags: Optical Composite Image Level Optical Composite Image Level suppliers China Optical Composite Image Level Optical Composite Image Level factory stable Optical Composite Image Level

 

Product Parameter

 

Technical parameters

- Plate kukosha dial 0.01 mm/m

- Kuyera chiyero 0-10 millimita / mita

- Parent-child error within ± 1mm/m+0.01 mm/m

- The parental error within the entire measurement range is ± 0. 02 millimeters/meter

- Bhenji flatness kutsauka kwe0.003mm

-Kukosha kwesero kuunganidza chiyero 0.1 millimeters/mita

- Hofisi dhesiki saizi 165 x 48 mamirimita

- Net uremu 2.2 makirogiramu

 

Read More About optical composite image level

 

 

Optical Composite Image Level Maintenance: Antirust Oil & Storage Tips

 

Proper maintenance ensures your optical composite image level retains its 0.01mm/m precision and durability. Follow these steps to protect its prism technology and mechanical components:

 

1. Daily Cleaning for Surface Protection

 

After use, wipe working surfaces (V-groove, edges, lenses) with isopropyl alcohol on a lint-free cloth to remove oils and dust. Use a soft brush for stubborn debris—never abrasives, which can scratch optical parts or damage metal coatings. This preserves the precision ground surfaces (Ra ≤ 0.1μm) critical for accurate readings.

 

2. Routine Antirust Care for Metal Parts

 

While the granite base resists corrosion, metal components (screws, levers, hinges) need protection. Apply Storaen’s non-acidic anti-rust oil every 3 months or after moisture exposure:

 

Apply thinly to threads and pivots with a dropper, avoiding pooling on granite/lenses.
Prevents seizing: Maintains lever mechanism sensitivity (0.001mm precision) for cylindrical slope measurements.

 

3. Optimal Storage Practices

 

Store in the included hard case or a dry cabinet to avoid temperature/humidity damage:

 

Environment: 10°C–30°C, <60% humidity to prevent lens condensation and optical distortion.
Positioning: Lay flat or upright in padded slots; never under heavy objects to avoid misaligning the optical system.
Long-term storage: Reapply anti-rust oil and add a silica packet; inspect 24 hours before use, verifying zero position via 180° rotation calibration.

 

4. Monthly Functional Inspections

 

Check performance regularly to ensure reliability:

 

Bubble clarity: Confirm the composite bubble image aligns smoothly without blur.
Lever movement: Test micro-screws for smooth rotation—stiffness signals needed lubrication.
Flatness check: Use a reference plate to validate factory-calibrated flatness (±0.0003mm/m).

 

5. Storaen’s Support for Longevity

 

Leverage our expert services to maintain peak performance:

 

Factory recalibration: Restores 0.01mm/m precision via ISO-certified equipment for critical applications.
Genuine parts: Replacement components ensure compatibility and preserve original accuracy.

 

By following these steps, your Storaen optical composite image level will deliver consistent precision for industrial alignment tasks, backed by our 30+ years of engineering expertise.

 

Zero Position Calibration of Optical Composite Image Level: 180° Rotation Method Explained

 

Accurate zero calibration is vital for your Storaen optical composite image level to maintain its 0.01mm/m precision and ±0.0003mm/m flatness. The 180° rotation method eliminates subtle optical or mechanical shifts, ensuring reliable measurements in critical tasks like CNC machine alignment or aerospace component inspection. Here’s a streamlined, step-by-step guide:

 

1. Why Calibrate?

 

Impacts, vibrations, or temperature fluctuations can shift the level’s zero reference, leading to measurement drift. Calibration realigns the bubble vial with the tool’s optical prism and lever system, ensuring consistent baselines for industrial applications where 0.001mm deviations are unacceptable—such as verifying machine tool guides or structural frameworks.

 

2. Setup Requirements

 

Storaen optical composite image level (featuring a V-grooved base and micro-adjusting screw)
Certified precision reference flat (e.g., our Storaen granite surface plate, with flatness ≤0.0002mm/m)
A clean, vibration-free workbench in a temperature-stabilized environment (18°C–22°C recommended)

 

3. Step 1: Initial Measurement

 

Place the level lengthwise on the reference flat, aligning the V-grooved base with the flat’s central axis. Rotate the micro-adjusting screw until the composite bubble image—created by the 45° prism system—perfectly overlaps in the viewfinder. Record this initial scale reading (A), which reflects the current deviation from true zero.

 

4. Step 2: 180° Rotation & Second Reading

 

Carefully flip the level 180° end-to-end while maintaining its longitudinal orientation on the flat (avoid any lateral movement). Adjust the micro-screw again to align the bubble image and record the new reading (B). The difference Δ = |A - B| indicates zero position error; ideal values for Storaen levels should be ≤0.005mm/m.

 

5. Step 3: Error Correction & Verification

 

Calculate the target zero position as the midpoint: C = (A + B)/2. Loosen the protective cap on the zero-adjustment screw (typically located near the bubble vial), rotate the screw until the scale reads C, then retighten. Repeat Steps 3–4 until Δ ≤0.002mm/m, ensuring minimal residual error.

 

6. Pro Tips for Precision

 

Triple-Check Consistency: Perform 3 calibration cycles, especially after transporting the level or working in environments with temperature swings, to ensure repeatable results.
Lubricate Moving Parts: Apply a drop of Storaen’s non-acidic oil to the micro-screw before adjustment to ensure smooth, backlash-free operation and prevent binding.
Environmental Control: Avoid calibrating near heat sources or drafts, as even minor temperature gradients can affect the granite base’s dimensional stability and introduce errors.

 

7. Storaen’s Calibration Support

 

Every Storaen optical composite image level includes a NIST-traceable calibration certificate, but quarterly in-field checks are recommended for heavy use. Our support includes:

 

Factory Recalibration: Restoring original 0.01mm/m accuracy using laser interferometers for high-stakes applications.
Genuine Spare Parts: Readily available adjustment screws and maintenance kits for long-term usability.
Video Tutorials & Expert Guidance: Step-by-step videos and engineer support to assist with on-site calibration procedures.

 

Final Notes

 

Mastering the 180° rotation method ensures your Storaen optical composite image level delivers the precision required for cylindrical slope measurements, machine tool flatness checks, and other critical alignments. With proper calibration, this tool, backed by our 30+ years of engineering expertise, becomes an indispensable asset in your quality control workflow, ensuring every measurement is as reliable as the first.

RELATED NEWS

Kana iwe uchifarira zvigadzirwa zvedu, unogona kusarudza kusiya ruzivo rwako pano, uye isu tichabatana newe munguva pfupi.


Asset 3

Need Help?
Drop us a message using the form below.