Kiwango cha picha ya mchanganyiko wa macho hutumiwa sana katika kupima gradient za uso wa gorofa na uso wa silinda hadi mwelekeo mlalo; Usawa wa ndege na unyoofu wa njia ya slaidi au msingi wa zana ya mashine au chombo cha macho cha mitambo pamoja na usahihi wa kusakinisha nafasi ya kifaa.
(1) kila thamani ya kuhitimu: ...0.01mm/m
(2) upeo wa juu wa kipimo: ...0~10mm/m
(3) posho: ...1mm/ndani ya mita moja... 0.01mm/m
Ndani ya masafa kamili ya kupimia...0.02mm/m
(4) kupotoka kwa ndege kwenye uso wa kazi...0.0003mm/m
(5) kila thamani ya kuhitimu ya kiwango cha roho...0.1mm/m
(6) uso wa kazi (LW): ...165 48mm
(7) uzito wavu wa chombo: ...2kgs.
Kiwango cha picha cha mchanganyiko hasa kinajumuisha sehemu zifuatazo kama vile skrubu ndogo ya kurekebisha, nati, diski iliyofuzu, kiwango cha roho, mche, kioo cha kukuza, leva pamoja na msingi ulio na sehemu ya kufanyia kazi isiyo na rangi na v.
Kiwango cha picha cha mchanganyiko hutumia prism kupata picha za viputo vya hewa katika kiwango cha utunzi cha roho na kukuzwa ili kuimarisha usahihi wa usomaji na hutumia lever na mfumo wa kutuma skrubu ndogo ili kuboresha usikivu wa kusoma. Kwa hivyo ikiwa kipengee cha kazi chenye kipenyo cha 0.01mm/m, kinaweza kusomwa kwa usahihi katika kiwango cha picha cha mchanganyiko (kiwango cha roho katika kiwango cha picha cha mchanganyiko hucheza jukumu la kuonyesha sifuri).
Weka kiwango cha picha cha mchanganyiko kwenye uso wa kazi wa kazi ya kupima na gradient ya workpiece ya kupima husababisha uncoincide ya picha za Bubble hewa tow; Zungusha diski iliyohitimu hadi picha za viputo vya kuvuta hewa zipatane na usomaji unaweza kupatikana mara moja. Gradient halisi ya kifaa cha kupima inaweza kuhesabiwa kwa formula ifuatayo:
Upinde rangi halisi=thamani ya upinde rangi usomaji wa Diski ya Fulcrum
Mfano wa Fox: Usomaji wa diski: 5 gradients; Kiwango hiki cha picha cha mchanganyiko hukumbwa na mbweha na thamani yake ya upinde rangi na umbali wa fulcrum, hiyo ni thamani ya gradient: 0.01mm/m na umbali wa fulcrum: 165mm.
Kwa hivyo: gradient halisi=165mm 5 0.01/1000=0.00825mm
(1) kabla ya matumizi, safisha vumbi la mafuta kwa petroli na kisha safisha kwa chachi ya kunyonya.
(2) Mabadiliko ya halijoto yana ushawishi mkubwa kwenye kifaa na kwa hivyo ni lazima itenganishwe na chanzo cha joto ili kuepusha hitilafu.
(3) Wakati wa kupima, zungusha diski iliyohitimu hadi picha za Bubble ya hewa ya kuvuta zilingane kabisa na kisha usomaji wa pande chanya na hasi uweze kuchukuliwa.
(4) If the instrument is found with in correct zero position, it may be adjusted; Put the instrument on a stable table and rotate the graduated disc to set the tow air bubble images coincide to get first reading a; Then turn the instrument by 180o and put back to its original place. Ra-rotate the graduated disc to get the tow air bubbles coincide to get the second reading b. So 1/2 (α +β ) is the zero deviation of the instrument. Loosen the three supporting screws on the graduated disc and press lightly by hand the embossed adjusting cap; Rotate the disc by 1/2 (α +β) to get the zero deviation and the point line composite; At last fasten the screws.
(5) Baada ya kazi, uso wa kazi wa chombo lazima usafishwe na kupakwa na asidi isiyo na asidi, isiyo na maji, mafuta ya antirust na karatasi ya antirust; Weka kwenye sanduku la mbao na uihifadhi mahali pakavu safi.
Hot Tags: Optical Composite Image Level Optical Composite Image Level suppliers China Optical Composite Image Level Optical Composite Image Level factory stable Optical Composite Image Level
Bidhaa Parameter
Vigezo vya kiufundi
- piga thamani ya sahani 0.01 mm/m
- Kipimo cha milimita 0-10 kwa mita
- Parent-child error within ± 1mm/m+0.01 mm/m
- The parental error within the entire measurement range is ± 0. 02 millimeters/meter
- Mkengeuko wa usawa wa benchi wa 0.003mm
- Kiwango cha mkusanyiko wa thamani ya seli milimita 0.1/mita
- Ukubwa wa dawati la ofisi 165 x 48 millimita
- Uzito wa jumla kilo 2.2
Proper maintenance ensures your optical composite image level retains its 0.01mm/m precision and durability. Follow these steps to protect its prism technology and mechanical components:
1. Daily Cleaning for Surface Protection
After use, wipe working surfaces (V-groove, edges, lenses) with isopropyl alcohol on a lint-free cloth to remove oils and dust. Use a soft brush for stubborn debris—never abrasives, which can scratch optical parts or damage metal coatings. This preserves the precision ground surfaces (Ra ≤ 0.1μm) critical for accurate readings.
2. Routine Antirust Care for Metal Parts
While the granite base resists corrosion, metal components (screws, levers, hinges) need protection. Apply Storaen’s non-acidic anti-rust oil every 3 months or after moisture exposure:
Apply thinly to threads and pivots with a dropper, avoiding pooling on granite/lenses.
Prevents seizing: Maintains lever mechanism sensitivity (0.001mm precision) for cylindrical slope measurements.
3. Optimal Storage Practices
Store in the included hard case or a dry cabinet to avoid temperature/humidity damage:
Environment: 10°C–30°C, <60% humidity to prevent lens condensation and optical distortion.
Positioning: Lay flat or upright in padded slots; never under heavy objects to avoid misaligning the optical system.
Long-term storage: Reapply anti-rust oil and add a silica packet; inspect 24 hours before use, verifying zero position via 180° rotation calibration.
4. Monthly Functional Inspections
Check performance regularly to ensure reliability:
Bubble clarity: Confirm the composite bubble image aligns smoothly without blur.
Lever movement: Test micro-screws for smooth rotation—stiffness signals needed lubrication.
Flatness check: Use a reference plate to validate factory-calibrated flatness (±0.0003mm/m).
5. Storaen’s Support for Longevity
Leverage our expert services to maintain peak performance:
Factory recalibration: Restores 0.01mm/m precision via ISO-certified equipment for critical applications.
Genuine parts: Replacement components ensure compatibility and preserve original accuracy.
By following these steps, your Storaen optical composite image level will deliver consistent precision for industrial alignment tasks, backed by our 30+ years of engineering expertise.
Accurate zero calibration is vital for your Storaen optical composite image level to maintain its 0.01mm/m precision and ±0.0003mm/m flatness. The 180° rotation method eliminates subtle optical or mechanical shifts, ensuring reliable measurements in critical tasks like CNC machine alignment or aerospace component inspection. Here’s a streamlined, step-by-step guide:
1. Why Calibrate?
Impacts, vibrations, or temperature fluctuations can shift the level’s zero reference, leading to measurement drift. Calibration realigns the bubble vial with the tool’s optical prism and lever system, ensuring consistent baselines for industrial applications where 0.001mm deviations are unacceptable—such as verifying machine tool guides or structural frameworks.
2. Setup Requirements
Storaen optical composite image level (featuring a V-grooved base and micro-adjusting screw)
Certified precision reference flat (e.g., our Storaen granite surface plate, with flatness ≤0.0002mm/m)
A clean, vibration-free workbench in a temperature-stabilized environment (18°C–22°C recommended)
3. Step 1: Initial Measurement
Place the level lengthwise on the reference flat, aligning the V-grooved base with the flat’s central axis. Rotate the micro-adjusting screw until the composite bubble image—created by the 45° prism system—perfectly overlaps in the viewfinder. Record this initial scale reading (A), which reflects the current deviation from true zero.
4. Step 2: 180° Rotation & Second Reading
Carefully flip the level 180° end-to-end while maintaining its longitudinal orientation on the flat (avoid any lateral movement). Adjust the micro-screw again to align the bubble image and record the new reading (B). The difference Δ = |A - B| indicates zero position error; ideal values for Storaen levels should be ≤0.005mm/m.
5. Step 3: Error Correction & Verification
Calculate the target zero position as the midpoint: C = (A + B)/2. Loosen the protective cap on the zero-adjustment screw (typically located near the bubble vial), rotate the screw until the scale reads C, then retighten. Repeat Steps 3–4 until Δ ≤0.002mm/m, ensuring minimal residual error.
6. Pro Tips for Precision
Triple-Check Consistency: Perform 3 calibration cycles, especially after transporting the level or working in environments with temperature swings, to ensure repeatable results.
Lubricate Moving Parts: Apply a drop of Storaen’s non-acidic oil to the micro-screw before adjustment to ensure smooth, backlash-free operation and prevent binding.
Environmental Control: Avoid calibrating near heat sources or drafts, as even minor temperature gradients can affect the granite base’s dimensional stability and introduce errors.
7. Storaen’s Calibration Support
Every Storaen optical composite image level includes a NIST-traceable calibration certificate, but quarterly in-field checks are recommended for heavy use. Our support includes:
Factory Recalibration: Restoring original 0.01mm/m accuracy using laser interferometers for high-stakes applications.
Genuine Spare Parts: Readily available adjustment screws and maintenance kits for long-term usability.
Video Tutorials & Expert Guidance: Step-by-step videos and engineer support to assist with on-site calibration procedures.
Final Notes
Mastering the 180° rotation method ensures your Storaen optical composite image level delivers the precision required for cylindrical slope measurements, machine tool flatness checks, and other critical alignments. With proper calibration, this tool, backed by our 30+ years of engineering expertise, becomes an indispensable asset in your quality control workflow, ensuring every measurement is as reliable as the first.
Kuhusiana BIDHAA
Thread Plug Gauge Requires Careful Handling
In the world of manufacturing and engineering, precision is non-negotiable—especially when it comes to threads, which are critical components in machinery, construction, and everyday products.
Surface plate calibration
In today's world, where precision and accuracy are crucial in various industries, the use of granite inspection tables and granite surface plates has become increasingly popular.
Ring Gauge Ensures Machining Accuracy
In the world of precision engineering, manufacturing, and quality control, accuracy is the cornerstone of reliability.