Optical Composite Image level Talosaga Oloa: O le optical composite image level e fa'aaogaina lautele i le fuaina o le fa'asolosolo o le mafolafola ma le cylindrical luga i le itu faalava; Le va'alele ma le sa'o o le ala fa'ase'e po'o le fa'avae o mea faigaluega masini po'o mea fa'ainisinia fa'apitoa fa'apea fo'i le sa'o o le fa'apipi'iina o mea faigaluega.

Fa'amatalaga

Fa'ailoga

Fa'amatalaga o oloa

 
  1. 1.Talosaga

O le maualuga o ata tu'ufa'atasia opitika o lo'o fa'aaogaina lautele i le fuaina o le fa'alili o le mafolafola ma le cylindrical luga i le fa'ata'amilosaga; Le va'alele ma le sa'o o le ala fa'ase'e po'o le fa'avae o masini masini po'o mea fa'ainisinia fa'apitoa fa'apea fo'i ma le sa'o o le fa'apipi'iina o mea faigaluega.

 

  1. 2. Faʻamatalaga faʻainisinia

(1) tau fa'au'uga ta'itasi: ...0.01mm/m

(2) maualuga fua fua: ...0~10mm/m

(3) alauni: ...1mm/i totonu o le mita e tasi... 0.01mm/m

I totonu ole fuataga atoa...0.02mm/m

(4) va'alele va'alele i luga o galuega...0.0003mm/m

(5) tau fa'au'uga ta'itasi o le tulaga agaga...0.1mm/m

(6) luga o galuega (LW): ...165 48mm

(7) mamafa mama o le meafaigaluega: ...2kgs.

  1.  
  2. 3. Fa'atulagaga o le meafaigaluega:

O le maualuga o ata tu'ufa'atasia e tele lava ina aofia ai vaega nei e pei o le micro adjusting screw, nati, fa'au'u tisiketi, tulaga agaga, prism, tioata fa'alautele, leve fa'apea fo'i ma le fa'avae i luga ole laiga ma le v galue.

 

  1. 4.Working mataupu faavae:

O le tulaga o ata tu'ufa'atasi e fa'aogaina ai le prism e maua ai ata o le ea i totonu o le agaga tu'ufa'atasia ma fa'alautele e fa'aleleia atili ai le sa'o o le faitau ma fa'aogaina le leve ma le micro screw transmitting system e fa'aleleia atili ai le faitau. O le mea lea, afai o le mea faigaluega ma le fa'alili o le 0.01mm/m, e mafai ona faitau sa'o i le tulaga o ata tu'ufa'atasi (o le tulaga o le agaga i le tulaga fa'atusa fa'atusa e tele lava ina ta'alo le sao o le fa'ailoaina ole zero).

 

  1. 5.Operating auala:

Tu'u le tulaga fa'atusa o ata i luga o le galuega o le fuaina o mea faigaluega ma le fa'alili ole fua ole mea faigaluega e mafua ai le le fetaui o ata tosoina o le ea; Fa'asolo le tisiketi fa'au'u se'ia o'o ina fetaui lelei ata ma e mafai ona maua vave le faitau. O le gradient moni o le mea faigaluega fua e mafai ona fuafuaina i le fua fa'atatau lea:

Fa'asa'o moni = tau fa'asa'o Fulcrum mamao Faitau tisiki

Fa'ata'ita'iga a Fox: Faitauga tisiki: 5 gradients; A'o fa'apipi'i le tulaga fa'atusa lenei ma lona tau fa'alili ma le mamao o le fa'a'ai, o le tau fa'alili: 0.01mm/m ma le mamao o le fulcrum: 165mm.

O lea: Fa'asa'o moni=165mm 5 0.01/1000=0.00825mm

  1.  
  2. 6. Fa'aaliga Fa'agaioiga:

(1) a'o le'i fa'aogaina, fa'amama ese le pefu suau'u i le penisini ona fa'amama lea i le kasa e fa'afefe.

(2) O le suiga o le vevela e tele sona aafiaga i luga o meafaigaluega ma o lea e tatau ai ona vavae ese ma le vevela e aloese ai mai mea sese.

(3) A'o fuaina, fe'avea'i le tisiketi fa'au'u se'ia fetaui lelei ata o le ea toso ona mafai lea ona fa'atino le faitauga i itu lelei ma le leaga.

(4) If the instrument is found with in correct zero position, it may be adjusted; Put the instrument on a stable table and rotate the graduated disc to set the tow air bubble images coincide to get first reading a; Then turn the instrument by 180o and put back to its original place. Ra-rotate the graduated disc to get the tow air bubbles coincide to get the second reading b. So 1/2 (α +β ) is the zero deviation of the instrument. Loosen the three supporting screws on the graduated disc and press lightly by hand the embossed adjusting cap; Rotate the disc by 1/2 (α +β) to get the zero deviation and the point line composite; At last fasten the screws.

(5) A maeʻa le galuega, e tatau ona faʻamamaina le mea faigaluega ma faʻapipiʻiina i le acid free, anhydrous, antirust suauʻu ma antirust pepa; Tuu i totonu o pusa laupapa ona teu lea i se nofoaga mama matutu.

 

Hot Tags: Optical Composite Image Level Optical Composite Image Level suppliers China Optical Composite Image Level Optical Composite Image Level factory stable Optical Composite Image Level

 

Fua Fa'atatau

 

Fa'agata fa'atekinisi

- vili tau ipu 0.01 mm/m

- Fuaina va'aiga 0-10 milimita/mita

- Parent-child error within ± 1mm/m+0.01 mm/m

- The parental error within the entire measurement range is ± 0. 02 millimeters/meter

- Se'esega mafolafola nofoa o le 0.003mm

- Tulaga tau fa'aputuga ole cell 0.1 milimita/mita

- Lapopo'a o le kesi Ofisa 165 x 48 milimita

- mamafa mama 2.2 kilokalama

 

Read More About optical composite image level

 

 

Optical Composite Image Level Maintenance: Antirust Oil & Storage Tips

 

Proper maintenance ensures your optical composite image level retains its 0.01mm/m precision and durability. Follow these steps to protect its prism technology and mechanical components:

 

1. Daily Cleaning for Surface Protection

 

After use, wipe working surfaces (V-groove, edges, lenses) with isopropyl alcohol on a lint-free cloth to remove oils and dust. Use a soft brush for stubborn debris—never abrasives, which can scratch optical parts or damage metal coatings. This preserves the precision ground surfaces (Ra ≤ 0.1μm) critical for accurate readings.

 

2. Routine Antirust Care for Metal Parts

 

While the granite base resists corrosion, metal components (screws, levers, hinges) need protection. Apply Storaen’s non-acidic anti-rust oil every 3 months or after moisture exposure:

 

Apply thinly to threads and pivots with a dropper, avoiding pooling on granite/lenses.
Prevents seizing: Maintains lever mechanism sensitivity (0.001mm precision) for cylindrical slope measurements.

 

3. Optimal Storage Practices

 

Store in the included hard case or a dry cabinet to avoid temperature/humidity damage:

 

Environment: 10°C–30°C, <60% humidity to prevent lens condensation and optical distortion.
Positioning: Lay flat or upright in padded slots; never under heavy objects to avoid misaligning the optical system.
Long-term storage: Reapply anti-rust oil and add a silica packet; inspect 24 hours before use, verifying zero position via 180° rotation calibration.

 

4. Monthly Functional Inspections

 

Check performance regularly to ensure reliability:

 

Bubble clarity: Confirm the composite bubble image aligns smoothly without blur.
Lever movement: Test micro-screws for smooth rotation—stiffness signals needed lubrication.
Flatness check: Use a reference plate to validate factory-calibrated flatness (±0.0003mm/m).

 

5. Storaen’s Support for Longevity

 

Leverage our expert services to maintain peak performance:

 

Factory recalibration: Restores 0.01mm/m precision via ISO-certified equipment for critical applications.
Genuine parts: Replacement components ensure compatibility and preserve original accuracy.

 

By following these steps, your Storaen optical composite image level will deliver consistent precision for industrial alignment tasks, backed by our 30+ years of engineering expertise.

 

Zero Position Calibration of Optical Composite Image Level: 180° Rotation Method Explained

 

Accurate zero calibration is vital for your Storaen optical composite image level to maintain its 0.01mm/m precision and ±0.0003mm/m flatness. The 180° rotation method eliminates subtle optical or mechanical shifts, ensuring reliable measurements in critical tasks like CNC machine alignment or aerospace component inspection. Here’s a streamlined, step-by-step guide:

 

1. Why Calibrate?

 

Impacts, vibrations, or temperature fluctuations can shift the level’s zero reference, leading to measurement drift. Calibration realigns the bubble vial with the tool’s optical prism and lever system, ensuring consistent baselines for industrial applications where 0.001mm deviations are unacceptable—such as verifying machine tool guides or structural frameworks.

 

2. Setup Requirements

 

Storaen optical composite image level (featuring a V-grooved base and micro-adjusting screw)
Certified precision reference flat (e.g., our Storaen granite surface plate, with flatness ≤0.0002mm/m)
A clean, vibration-free workbench in a temperature-stabilized environment (18°C–22°C recommended)

 

3. Step 1: Initial Measurement

 

Place the level lengthwise on the reference flat, aligning the V-grooved base with the flat’s central axis. Rotate the micro-adjusting screw until the composite bubble image—created by the 45° prism system—perfectly overlaps in the viewfinder. Record this initial scale reading (A), which reflects the current deviation from true zero.

 

4. Step 2: 180° Rotation & Second Reading

 

Carefully flip the level 180° end-to-end while maintaining its longitudinal orientation on the flat (avoid any lateral movement). Adjust the micro-screw again to align the bubble image and record the new reading (B). The difference Δ = |A - B| indicates zero position error; ideal values for Storaen levels should be ≤0.005mm/m.

 

5. Step 3: Error Correction & Verification

 

Calculate the target zero position as the midpoint: C = (A + B)/2. Loosen the protective cap on the zero-adjustment screw (typically located near the bubble vial), rotate the screw until the scale reads C, then retighten. Repeat Steps 3–4 until Δ ≤0.002mm/m, ensuring minimal residual error.

 

6. Pro Tips for Precision

 

Triple-Check Consistency: Perform 3 calibration cycles, especially after transporting the level or working in environments with temperature swings, to ensure repeatable results.
Lubricate Moving Parts: Apply a drop of Storaen’s non-acidic oil to the micro-screw before adjustment to ensure smooth, backlash-free operation and prevent binding.
Environmental Control: Avoid calibrating near heat sources or drafts, as even minor temperature gradients can affect the granite base’s dimensional stability and introduce errors.

 

7. Storaen’s Calibration Support

 

Every Storaen optical composite image level includes a NIST-traceable calibration certificate, but quarterly in-field checks are recommended for heavy use. Our support includes:

 

Factory Recalibration: Restoring original 0.01mm/m accuracy using laser interferometers for high-stakes applications.
Genuine Spare Parts: Readily available adjustment screws and maintenance kits for long-term usability.
Video Tutorials & Expert Guidance: Step-by-step videos and engineer support to assist with on-site calibration procedures.

 

Final Notes

 

Mastering the 180° rotation method ensures your Storaen optical composite image level delivers the precision required for cylindrical slope measurements, machine tool flatness checks, and other critical alignments. With proper calibration, this tool, backed by our 30+ years of engineering expertise, becomes an indispensable asset in your quality control workflow, ensuring every measurement is as reliable as the first.