Mafotokozedwe Akatundu
Mulingo wa chithunzi chophatikizika chowoneka bwino umagwiritsidwa ntchito kwambiri kuyeza ma gradients apansi athyathyathya ndi pamwamba pa cylindrical kupita kunjira yopingasa; Mayendedwe a ndege ndi kuwongoka kwa slideway kapena maziko a zida zamakina kapena zida zamakina owoneka bwino komanso kulondola koyikira zida.
(1) mtengo uliwonse womaliza: ...0.01mm/m
(2) kuchuluka kwa kuyeza: ...0~10mm/m
(3) malipiro: ...1mm/mkati mwa mita imodzi... 0.01mm/m
Muyezo wathunthu...0.02mm/m
(4) kupatuka kwa ndege pamalo ogwirira ntchito...0.0003mm/m
(5) mtengo uliwonse wa maphunziro a msinkhu wa mzimu...0.1mm/m
(6) ntchito pamwamba (LW): ...165 48mm
(7) kulemera kwa chida: ...2kgs.
Mulingo wazithunzi zophatikizika makamaka umakhala ndi magawo otsatirawa monga zomangira zazing'ono, nati, disiki yomaliza, mulingo wa mzimu, prism, galasi lokulitsa, lever komanso maziko okhala ndi plain ndi v yogwirira ntchito.
Mulingo wazithunzi zophatikizika umagwiritsa ntchito prism kuti zithunzi za kuwira kwa mpweya zikhale zophatikizika ndi kukulitsidwa kuti ziwongolere kuwerenga bwino komanso kugwiritsa ntchito lever ndi micro screw transmitting system kuti muzitha kuwerenga bwino. Chifukwa chake ngati chogwirira ntchito chokhala ndi gradient ya 0.01mm/m, chitha kuwerengedwa molondola mulingo wazithunzi zophatikizika (mulingo wamzimu pazithunzi zophatikizika makamaka umagwira ntchito yowonetsa ziro).
Ikani chithunzi chophatikizika pagawo logwira ntchito la ntchito yoyezera ndipo gradient ya choyezera choyezera chimayambitsa kusamvana kwa zithunzi za tow air kuwira; Tembenuzani diski yomaliza mpaka zithunzi za thovu la mpweya zigwirizana ndipo kuwerenga kutha kupezeka nthawi yomweyo. The gradient yeniyeni ya workpiece yoyezera imatha kuwerengedwa motsatira njira iyi:
Maonekedwe enieni=mtengo wapatali wa Fulcrum mtunda wowerengera Diski
Chitsanzo cha Fox: Kuwerenga kwa disc: 5 gradients; Popeza mulingo wazithunzi waphatikizidwewu uli ndi mtengo wake wopendekera komanso mtunda wa fulcrum, ndiye kuti mtengo wake ndi 0.01mm/m ndi mtunda wa fulcrum: 165mm.
Choncho: gradient weniweni = 165mm 5 0.01/1000=0.00825mm
(1) Musanagwiritse ntchito, chotsani fumbi lamafuta ndi petulo ndikuyeretsani ndi gauze woyamwa.
(2) Kusintha kwa kutentha kumakhudza kwambiri chida ndipo chifukwa chake kuyenera kupatulidwa ndi gwero la kutentha kuti zisawonongeke.
(3) Poyezera, tembenuzani diski yomaliza mpaka zithunzi za thovu la mpweya zigwirizane kwathunthu ndiyeno zowerengera zonse zabwino ndi zoyipa zitha kutengedwa.
(4) If the instrument is found with in correct zero position, it may be adjusted; Put the instrument on a stable table and rotate the graduated disc to set the tow air bubble images coincide to get first reading a; Then turn the instrument by 180o and put back to its original place. Ra-rotate the graduated disc to get the tow air bubbles coincide to get the second reading b. So 1/2 (α +β ) is the zero deviation of the instrument. Loosen the three supporting screws on the graduated disc and press lightly by hand the embossed adjusting cap; Rotate the disc by 1/2 (α +β) to get the zero deviation and the point line composite; At last fasten the screws.
(5) Pambuyo pa ntchito, malo ogwirira ntchito a chipangizocho ayenera kutsukidwa ndi kupakidwa ndi asidi wopanda, anhydrous, mafuta oletsa antirust ndi pepala lotsutsa; Ikani mu bokosi lamatabwa ndikusunga pamalo aukhondo ouma.
Hot Tags: Optical Composite Image Level Optical Composite Image Level suppliers China Optical Composite Image Level Optical Composite Image Level factory stable Optical Composite Image Level
Product Parameter
Zosintha zaukadaulo
- Mtengo wa mbale kuyimba 0.01 mm/m
- Miyezo osiyanasiyana 0-10 mamilimita/mita
- Parent-child error within ± 1mm/m+0.01 mm/m
- The parental error within the entire measurement range is ± 0. 02 millimeters/meter
- Bench flatness kupatuka kwa 0.003mm
- Kuchuluka kwa ma cell 0.1 millimeters/mita
- Kukula kwa desiki yakuofesi 165 x 48 millimeters
- Net kulemera 2.2 kilograms
Proper maintenance ensures your optical composite image level retains its 0.01mm/m precision and durability. Follow these steps to protect its prism technology and mechanical components:
1. Daily Cleaning for Surface Protection
After use, wipe working surfaces (V-groove, edges, lenses) with isopropyl alcohol on a lint-free cloth to remove oils and dust. Use a soft brush for stubborn debris—never abrasives, which can scratch optical parts or damage metal coatings. This preserves the precision ground surfaces (Ra ≤ 0.1μm) critical for accurate readings.
2. Routine Antirust Care for Metal Parts
While the granite base resists corrosion, metal components (screws, levers, hinges) need protection. Apply Storaen’s non-acidic anti-rust oil every 3 months or after moisture exposure:
Apply thinly to threads and pivots with a dropper, avoiding pooling on granite/lenses.
Prevents seizing: Maintains lever mechanism sensitivity (0.001mm precision) for cylindrical slope measurements.
3. Optimal Storage Practices
Store in the included hard case or a dry cabinet to avoid temperature/humidity damage:
Environment: 10°C–30°C, <60% humidity to prevent lens condensation and optical distortion.
Positioning: Lay flat or upright in padded slots; never under heavy objects to avoid misaligning the optical system.
Long-term storage: Reapply anti-rust oil and add a silica packet; inspect 24 hours before use, verifying zero position via 180° rotation calibration.
4. Monthly Functional Inspections
Check performance regularly to ensure reliability:
Bubble clarity: Confirm the composite bubble image aligns smoothly without blur.
Lever movement: Test micro-screws for smooth rotation—stiffness signals needed lubrication.
Flatness check: Use a reference plate to validate factory-calibrated flatness (±0.0003mm/m).
5. Storaen’s Support for Longevity
Leverage our expert services to maintain peak performance:
Factory recalibration: Restores 0.01mm/m precision via ISO-certified equipment for critical applications.
Genuine parts: Replacement components ensure compatibility and preserve original accuracy.
By following these steps, your Storaen optical composite image level will deliver consistent precision for industrial alignment tasks, backed by our 30+ years of engineering expertise.
Accurate zero calibration is vital for your Storaen optical composite image level to maintain its 0.01mm/m precision and ±0.0003mm/m flatness. The 180° rotation method eliminates subtle optical or mechanical shifts, ensuring reliable measurements in critical tasks like CNC machine alignment or aerospace component inspection. Here’s a streamlined, step-by-step guide:
1. Why Calibrate?
Impacts, vibrations, or temperature fluctuations can shift the level’s zero reference, leading to measurement drift. Calibration realigns the bubble vial with the tool’s optical prism and lever system, ensuring consistent baselines for industrial applications where 0.001mm deviations are unacceptable—such as verifying machine tool guides or structural frameworks.
2. Setup Requirements
Storaen optical composite image level (featuring a V-grooved base and micro-adjusting screw)
Certified precision reference flat (e.g., our Storaen granite surface plate, with flatness ≤0.0002mm/m)
A clean, vibration-free workbench in a temperature-stabilized environment (18°C–22°C recommended)
3. Step 1: Initial Measurement
Place the level lengthwise on the reference flat, aligning the V-grooved base with the flat’s central axis. Rotate the micro-adjusting screw until the composite bubble image—created by the 45° prism system—perfectly overlaps in the viewfinder. Record this initial scale reading (A), which reflects the current deviation from true zero.
4. Step 2: 180° Rotation & Second Reading
Carefully flip the level 180° end-to-end while maintaining its longitudinal orientation on the flat (avoid any lateral movement). Adjust the micro-screw again to align the bubble image and record the new reading (B). The difference Δ = |A - B| indicates zero position error; ideal values for Storaen levels should be ≤0.005mm/m.
5. Step 3: Error Correction & Verification
Calculate the target zero position as the midpoint: C = (A + B)/2. Loosen the protective cap on the zero-adjustment screw (typically located near the bubble vial), rotate the screw until the scale reads C, then retighten. Repeat Steps 3–4 until Δ ≤0.002mm/m, ensuring minimal residual error.
6. Pro Tips for Precision
Triple-Check Consistency: Perform 3 calibration cycles, especially after transporting the level or working in environments with temperature swings, to ensure repeatable results.
Lubricate Moving Parts: Apply a drop of Storaen’s non-acidic oil to the micro-screw before adjustment to ensure smooth, backlash-free operation and prevent binding.
Environmental Control: Avoid calibrating near heat sources or drafts, as even minor temperature gradients can affect the granite base’s dimensional stability and introduce errors.
7. Storaen’s Calibration Support
Every Storaen optical composite image level includes a NIST-traceable calibration certificate, but quarterly in-field checks are recommended for heavy use. Our support includes:
Factory Recalibration: Restoring original 0.01mm/m accuracy using laser interferometers for high-stakes applications.
Genuine Spare Parts: Readily available adjustment screws and maintenance kits for long-term usability.
Video Tutorials & Expert Guidance: Step-by-step videos and engineer support to assist with on-site calibration procedures.
Final Notes
Mastering the 180° rotation method ensures your Storaen optical composite image level delivers the precision required for cylindrical slope measurements, machine tool flatness checks, and other critical alignments. With proper calibration, this tool, backed by our 30+ years of engineering expertise, becomes an indispensable asset in your quality control workflow, ensuring every measurement is as reliable as the first.
Zogwirizana PRODUCTS
Smart Monitoring Integration with Modern Gate Valve Types
The integration of smart monitoring systems with industrial equipment has revolutionized operational efficiency, safety, and maintenance practices.
Innovative Metal Mesh Strainer Designs for Modern Minimalist Kitchens
Modern minimalist kitchens prioritize functionality, clean lines, and durable materials.
Impact of Control Valve Maintenance on Pipeline Safety
Pipeline systems are the backbone of modern industrial infrastructure, enabling the efficient transport of liquids, gases, and other media across vast distances.