Deskrizzjoni tal-prodott
Il-livell ta 'immaġni kompost ottiku huwa użat ħafna fil-kejl tal-gradjenti ta' wiċċ ċatt u wiċċ ċilindriku għal direzzjoni orizzontali; Il-pjan ness u straightness ta slideway jew bażi ta ' l-għodda tal-magni jew strument mekkaniku ottiku kif ukoll il-korrettezza tal-pożizzjoni ta ' l-installazzjoni tat-tagħmir.
(1) kull valur tal-gradwazzjoni: ... 0.01mm/m
(2) medda ta 'kejl max: ... 0 ~ 10mm/m
(3) allowance: ... 1mm / fi ħdan metru wieħed ... 0.01mm / m
Fil-medda sħiħa tal-kejl...0.02mm/m
(4) devjazzjoni tal-pjan fuq il-wiċċ tax-xogħol... 0.0003mm/m
(5) kull valur ta 'gradwazzjoni tal-livell ta' l-ispirtu...0.1mm/m
(6) wiċċ tax-xogħol (LW): ...165 48mm
(7) piż nett ta ' l-istrument: ... 2kgs.
Il-livell ta 'immaġni kompost jikkonsisti prinċipalment fil-partijiet li ġejjin bħal kamin ta' aġġustament mikro, ġewż, diska gradwata, livell ta 'spirtu, priżma, lenti, lieva kif ukoll bażi b'wiċċ tax-xogħol sempliċi u v.
Il-livell tal-immaġni kompost juża priżma biex jikseb l-immaġini tal-bużżieqa tal-arja fil-kompost tal-livell tal-ispirtu u mkabbar biex itejjeb l-eżattezza tal-qari u juża sistema ta 'trażmissjoni ta' lieva u mikro kamin biex itejjeb is-sensibilità tal-qari. Għalhekk jekk il-biċċa tax-xogħol bi gradjent ta '0.01mm/m, tista' tinqara b'mod preċiż fil-livell ta 'immaġni kompost (il-livell ta' l-ispirtu fil-livell ta 'immaġni kompost prinċipalment għandu r-rwol li jindika żero).
Poġġi l-livell tal-immaġni kompost fuq il-wiċċ tax-xogħol tal-biċċa tax-xogħol tal-kejl u l-gradjent tal-biċċa tax-xogħol tal-kejl tikkawża uncoincide tal-immaġini tal-bużżieqa tal-arja tal-irmonk; Dawwar id-diska gradwata sakemm l-immaġini tal-bużżieqa tal-irmunkar tal-arja jikkoinċidu u l-qari jista' jinkiseb immedjatament. Il-gradjent attwali tal-biċċa tax-xogħol tal-kejl jista 'jiġi kkalkulat bil-formula li ġejja:
Grajjent attwali=valur tal-gradjent Distanza tal-Fulcrum Qari tad-diska
Eżempju tal-volpi: Qari tad-diska: 5 gradjenti; Peress li dan il-livell ta 'immaġni kompost huwa foxed bil-valur tal-gradjent tiegħu u d-distanza tal-fulkru, jiġifieri l-valur tal-gradjent: 0.01mm/m u d-distanza tal-fulkru: 165mm.
Allura: gradjent attwali = 165mm 5 0.01/1000 = 0.00825mm
(1) qabel l-użu, naddaf it-trab taż-żejt bil-gażolina u mbagħad naddaf b'garża assorbenti.
(2) Il-bidla fit-temperatura għandha influwenza kbira fuq l-istrument u għalhekk għandha tkun separata b'sors tas-sħana biex tevita żball.
(3) Waqt il-kejl, dawwar id-diska gradwata sakemm l-immaġini tal-bużżieqa tal-irmunkar tal-arja jikkoinċidu kompletament u mbagħad jista 'jittieħu l-qari kemm fuq direzzjonijiet pożittivi kif ukoll negattivi.
(4) If the instrument is found with in correct zero position, it may be adjusted; Put the instrument on a stable table and rotate the graduated disc to set the tow air bubble images coincide to get first reading a; Then turn the instrument by 180o and put back to its original place. Ra-rotate the graduated disc to get the tow air bubbles coincide to get the second reading b. So 1/2 (α +β ) is the zero deviation of the instrument. Loosen the three supporting screws on the graduated disc and press lightly by hand the embossed adjusting cap; Rotate the disc by 1/2 (α +β) to get the zero deviation and the point line composite; At last fasten the screws.
(5) Wara x-xogħol, il-wiċċ tax-xogħol tal-istrument għandu jitnaddaf u miksi b'karta mingħajr aċidu, anidru, antisadid u karta antisadid; Poġġiha f'kaxxa tal-injam u mbagħad aħżen f'post nadif u niexef.
Hot Tags: Optical Composite Image Level Optical Composite Image Level suppliers China Optical Composite Image Level Optical Composite Image Level factory stable Optical Composite Image Level
Parametru tal-Prodott
Parametri tekniċi
- Dial tal-valur tal-pjanċa 0.01 mm/m
- Medda ta 'kejl 0-10 millimetri/metru
- Parent-child error within ± 1mm/m+0.01 mm/m
- The parental error within the entire measurement range is ± 0. 02 millimeters/meter
- Devjazzjoni tal-flatness tal-bank ta '0.003mm
- Standard ta 'akkumulazzjoni tal-valur taċ-ċelluli 0.1 millimetri/metru
- Id-daqs tal-iskrivanija tal-uffiċċju 165 x 48 millimetru
- Piż nett 2.2 kilogrammi
Proper maintenance ensures your optical composite image level retains its 0.01mm/m precision and durability. Follow these steps to protect its prism technology and mechanical components:
1. Daily Cleaning for Surface Protection
After use, wipe working surfaces (V-groove, edges, lenses) with isopropyl alcohol on a lint-free cloth to remove oils and dust. Use a soft brush for stubborn debris—never abrasives, which can scratch optical parts or damage metal coatings. This preserves the precision ground surfaces (Ra ≤ 0.1μm) critical for accurate readings.
2. Routine Antirust Care for Metal Parts
While the granite base resists corrosion, metal components (screws, levers, hinges) need protection. Apply Storaen’s non-acidic anti-rust oil every 3 months or after moisture exposure:
Apply thinly to threads and pivots with a dropper, avoiding pooling on granite/lenses.
Prevents seizing: Maintains lever mechanism sensitivity (0.001mm precision) for cylindrical slope measurements.
3. Optimal Storage Practices
Store in the included hard case or a dry cabinet to avoid temperature/humidity damage:
Environment: 10°C–30°C, <60% humidity to prevent lens condensation and optical distortion.
Positioning: Lay flat or upright in padded slots; never under heavy objects to avoid misaligning the optical system.
Long-term storage: Reapply anti-rust oil and add a silica packet; inspect 24 hours before use, verifying zero position via 180° rotation calibration.
4. Monthly Functional Inspections
Check performance regularly to ensure reliability:
Bubble clarity: Confirm the composite bubble image aligns smoothly without blur.
Lever movement: Test micro-screws for smooth rotation—stiffness signals needed lubrication.
Flatness check: Use a reference plate to validate factory-calibrated flatness (±0.0003mm/m).
5. Storaen’s Support for Longevity
Leverage our expert services to maintain peak performance:
Factory recalibration: Restores 0.01mm/m precision via ISO-certified equipment for critical applications.
Genuine parts: Replacement components ensure compatibility and preserve original accuracy.
By following these steps, your Storaen optical composite image level will deliver consistent precision for industrial alignment tasks, backed by our 30+ years of engineering expertise.
Accurate zero calibration is vital for your Storaen optical composite image level to maintain its 0.01mm/m precision and ±0.0003mm/m flatness. The 180° rotation method eliminates subtle optical or mechanical shifts, ensuring reliable measurements in critical tasks like CNC machine alignment or aerospace component inspection. Here’s a streamlined, step-by-step guide:
1. Why Calibrate?
Impacts, vibrations, or temperature fluctuations can shift the level’s zero reference, leading to measurement drift. Calibration realigns the bubble vial with the tool’s optical prism and lever system, ensuring consistent baselines for industrial applications where 0.001mm deviations are unacceptable—such as verifying machine tool guides or structural frameworks.
2. Setup Requirements
Storaen optical composite image level (featuring a V-grooved base and micro-adjusting screw)
Certified precision reference flat (e.g., our Storaen granite surface plate, with flatness ≤0.0002mm/m)
A clean, vibration-free workbench in a temperature-stabilized environment (18°C–22°C recommended)
3. Step 1: Initial Measurement
Place the level lengthwise on the reference flat, aligning the V-grooved base with the flat’s central axis. Rotate the micro-adjusting screw until the composite bubble image—created by the 45° prism system—perfectly overlaps in the viewfinder. Record this initial scale reading (A), which reflects the current deviation from true zero.
4. Step 2: 180° Rotation & Second Reading
Carefully flip the level 180° end-to-end while maintaining its longitudinal orientation on the flat (avoid any lateral movement). Adjust the micro-screw again to align the bubble image and record the new reading (B). The difference Δ = |A - B| indicates zero position error; ideal values for Storaen levels should be ≤0.005mm/m.
5. Step 3: Error Correction & Verification
Calculate the target zero position as the midpoint: C = (A + B)/2. Loosen the protective cap on the zero-adjustment screw (typically located near the bubble vial), rotate the screw until the scale reads C, then retighten. Repeat Steps 3–4 until Δ ≤0.002mm/m, ensuring minimal residual error.
6. Pro Tips for Precision
Triple-Check Consistency: Perform 3 calibration cycles, especially after transporting the level or working in environments with temperature swings, to ensure repeatable results.
Lubricate Moving Parts: Apply a drop of Storaen’s non-acidic oil to the micro-screw before adjustment to ensure smooth, backlash-free operation and prevent binding.
Environmental Control: Avoid calibrating near heat sources or drafts, as even minor temperature gradients can affect the granite base’s dimensional stability and introduce errors.
7. Storaen’s Calibration Support
Every Storaen optical composite image level includes a NIST-traceable calibration certificate, but quarterly in-field checks are recommended for heavy use. Our support includes:
Factory Recalibration: Restoring original 0.01mm/m accuracy using laser interferometers for high-stakes applications.
Genuine Spare Parts: Readily available adjustment screws and maintenance kits for long-term usability.
Video Tutorials & Expert Guidance: Step-by-step videos and engineer support to assist with on-site calibration procedures.
Final Notes
Mastering the 180° rotation method ensures your Storaen optical composite image level delivers the precision required for cylindrical slope measurements, machine tool flatness checks, and other critical alignments. With proper calibration, this tool, backed by our 30+ years of engineering expertise, becomes an indispensable asset in your quality control workflow, ensuring every measurement is as reliable as the first.
Relatati PRODOTTI
Small Hole Gauge Use in Aerospace Component Testing
In the aerospace industry, where component reliability can mean the difference between safe flight and catastrophic failure, precision measurement is not just a requirement—it's a matter of life and death.
Flanged Strainer Use in Marine Environments
Marine environments pose unique challenges for industrial equipment, from relentless saltwater corrosion to high-pressure systems and fluctuating temperatures.
Affordable Welding Tables for Educational Workshops
In educational workshops—whether for high school metalworking classes, community college trade programs, or adult learning centers—having the right equipment is essential for fostering skill development, ensuring safety, and staying within budget.